Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
J Prosthet Dent ; 2023 Oct 30.
Artigo em Inglês | MEDLINE | ID: mdl-37914607

RESUMO

STATEMENT OF PROBLEM: The weight of larger obturators places increased stress on the supportive teeth and bearing tissue and allows gravity to act as a dislodging factor affecting the stability and retention of the prosthesis. However, whether conventionally processed and 3-dimensionally (3D) printed hollow obturators have similar reduced weights compared with solid obturators is unclear. PURPOSE: The purpose of this in vitro study was to evaluate the weight difference between conventionally heat-processed complete denture obturators with and without hollowing and 3D printed obturators with a hollow bulb. MATERIAL AND METHODS: Obturators were fabricated as conventionally heat-processed solid obturators, conventionally heat-processed with a hollow obturator bulb, and 3D printed with a hollow obturator bulb. Nine obturator prostheses were fabricated for each type of Aramany Class I, Class II, and Class III defect. The weights of each of the 27 obturator prostheses were measured, and a statistical analysis was performed with exact versions of the Kruskal-Wallis test or Wilcoxon Rank Sum test (α=.05). RESULTS: Conventionally heat-processed solid obturators were significantly heavier than the conventionally heat-processed hollow (P<.001) or the 3D printed hollow obturators (P<.001). No significant difference (P=.222) was found between the conventionally heat-processed hollow and 3D printed hollow obturators. The decrease in weight was proportional to the size of the defect with the Aramany Class I defect having the largest differences in weight between the different fabrication methods, followed by Class II, and then Class III with a much smaller defect. CONCLUSIONS: Additive manufacturing could be a suitable alternative to conventional techniques for the fabrication of a closed hollow obturator because of the comparable weights.

2.
Plast Reconstr Surg Glob Open ; 10(10): e4581, 2022 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-36225848

RESUMO

A 20-month-old boy presented with biopsy-proven recurrent alveolar rhabdomyosarcoma without metastasis. He was previously treated with multiagent chemotherapy and external beam irradiation showing a complete response. Upon relapse, he was treated with chemotherapy, orbital exenteration, and brachytherapy. Customized, intraoperative brachytherapy has potential to limit the sequelae associated with radiation adjuvant therapy.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...